Calculates a SHA-1 hash of a data block referenced by a physical address.
PPS_ENGINE pEngine
An opaque handle to an engine created by the EngCreateEngine function.
uint64_t Address
The physical address of the data to be hashed.
uint64_t cbToRead
Specifies how many bytes should be hashed.
PPS_SHA1_HASH pSha1Hash
The buffer that stores the hash data.
uint64_t* pcbRead
Returns the number of bytes that were actually hashed.
If the function succeeds, the return value is PULSE_STATUS_SUCCESS.
If it fails, it returns one of the PULSE_STATUS values. Possible return codes include, but are not limited to, the following:
| PULSE_STATUS_PARTIAL_READ0x00000001 | Only a portion of memory was read. Check the *pcbRead parameter value to determine how many bytes were read. |
| PULSE_STATUS_INSUFFICIENT_RESOURCES0xC0000002 | One of the memory allocations failed during initialization. |
| PULSE_STATUS_READ_FAILED0xC0000003 | Transport communication failed during a read operation. |
| PULSE_STATUS_WRITE_FAILED0xC0000004 | Transport communication failed during a write operation. |
| PULSE_STATUS_TIMEOUT0xC0000007 | Might happen if
|
| PULSE_STATUS_INVALID_PARAMETER0xC0000010 | Might happen if
|
| PULSE_STATUS_INVALID_PACKET0xC0000031 | An invalid or unexpected packet was received in response. |
| PULSE_STATUS_INVALID_TRANSLATION0xC0000021 | The specified physical address is above the maximum addressable on the target platform. |
| PULSE_STATUS_DEVICE_CONNECTION_LOST0xC0000308 | The connection to the transport was lost. Try restarting the engine or the transport. |
Partial reads may occur when address translation is not available beyond a certain point.